vendor_oneplus_sm8250-common/proprietary/vendor/etc/init/netmgrd.rc

78 lines
3.6 KiB
Plaintext
Raw Permalink Normal View History

# Copyright (c) 2019-2020 Qualcomm Technologies, Inc.
# All Rights Reserved.
# Confidential and Proprietary - Qualcomm Technologies, Inc.
#
on boot
#Create NETMGR daemon socket area
mkdir /dev/socket/netmgr 0750 radio radio
#Assign TCP buffer thresholds to be ceiling value of technology maximums
#Increased technology maximums should be reflected here.
write /proc/sys/net/core/rmem_max 16777216
write /proc/sys/net/core/wmem_max 8388608
#Load rmnet_core driver
exec u:r:vendor_modprobe:s0 -- /vendor/bin/modprobe -a -d /vendor/lib/modules rmnet_ctl
exec u:r:vendor_modprobe:s0 -- /vendor/bin/modprobe -a -d /vendor/lib/modules rmnet_core
exec u:r:vendor_modprobe:s0 -- /vendor/bin/modprobe -a -d /vendor/lib/modules/5.4-gki rmnet_ctl
exec u:r:vendor_modprobe:s0 -- /vendor/bin/modprobe -a -d /vendor/lib/modules/5.4-gki rmnet_core
# msm specific files that need to be created on /data
on post-fs-data
#Create NETMGR daemon log dir
mkdir /data/vendor/netmgr 0770 radio radio
chmod 0770 /data/vendor/netmgr
# Create netmgr recovery folder
mkdir /data/vendor/netmgr/recovery 0700 radio radio
chmod 0770 /data/vendor/netmgr/recovery
write /data/vendor/netmgr/recovery/recovery_info ""
chown radio radio /data/vendor/netmgr/recovery/recovery_info
# Manage netmgrd based on value of property
on property:persist.vendor.data.mode=disabled
stop vendor.netmgrd
service vendor.netmgrd /system/vendor/bin/netmgrd
class main
on property:ro.vendor.use_data_netmgrd=false
# netmgr not supported on specific target
stop vendor.netmgrd
on property:ro.baseband=apq
stop vendor.netmgrd
on property:persist.vendor.data.shs_ko_load=1
exec u:r:vendor_modprobe:s0 -- /vendor/bin/modprobe -a -d /vendor/lib/modules rmnet_shs
exec u:r:vendor_modprobe:s0 -- /vendor/bin/modprobe -a -d /vendor/lib/modules/5.4-gki rmnet_shs
on property:persist.vendor.data.shs_ko_load=0
exec u:r:vendor_modprobe:s0 -- /vendor/bin/modprobe -r -d /vendor/lib/modules rmnet_shs
exec u:r:vendor_modprobe:s0 -- /vendor/bin/modprobe -r -d /vendor/lib/modules/5.4-gki rmnet_shs
on property:persist.vendor.data.perf_ko_load=3
exec u:r:vendor_modprobe:s0 -- /vendor/bin/modprobe -d /vendor/lib/modules rmnet_perf rmnet_perf_ingress_deag=N
exec u:r:vendor_modprobe:s0 -- /vendor/bin/modprobe -d /vendor/lib/modules/5.4-gki rmnet_perf rmnet_perf_ingress_deag=N
on property:persist.vendor.data.perf_ko_load=2
exec u:r:vendor_modprobe:s0 -- /vendor/bin/modprobe -d /vendor/lib/modules rmnet_perf rmnet_perf_opt_mode="udp"
exec u:r:vendor_modprobe:s0 -- /vendor/bin/modprobe -d /vendor/lib/modules/5.4-gki rmnet_perf rmnet_perf_opt_mode="udp"
on property:persist.vendor.data.perf_ko_load=1
exec u:r:vendor_modprobe:s0 -- /vendor/bin/modprobe -a -d /vendor/lib/modules rmnet_perf
exec u:r:vendor_modprobe:s0 -- /vendor/bin/modprobe -a -d /vendor/lib/modules/5.4-gki rmnet_perf
on property:persist.vendor.data.perf_ko_load=0
exec u:r:vendor_modprobe:s0 -- /vendor/bin/modprobe -r -d /vendor/lib/modules rmnet_perf
exec u:r:vendor_modprobe:s0 -- /vendor/bin/modprobe -r -d /vendor/lib/modules/5.4-gki rmnet_perf
on property:persist.vendor.data.offload_ko_load=1
exec u:r:vendor_modprobe:s0 -- /vendor/bin/modprobe -a -d /vendor/lib/modules rmnet_offload
exec u:r:vendor_modprobe:s0 -- /vendor/bin/modprobe -a -d /vendor/lib/modules/5.4-gki rmnet_offload
on property:persist.vendor.data.offload_ko_load=0
exec u:r:vendor_modprobe:s0 -- /vendor/bin/modprobe -r -d /vendor/lib/modules rmnet_offload
exec u:r:vendor_modprobe:s0 -- /vendor/bin/modprobe -r -d /vendor/lib/modules/5.4-gki rmnet_offload